{"product_id":"remington-tr-01","title":"Used Line Power 2,500\/3,333 kVA dry-type motor-drive isolation transformer — 13.8 kV to 480Y\/277 V — TR-01","description":"\u003cp\u003e\u003cstrong\u003eCondition: Used.\u003c\/strong\u003e Untested industrial surplus. Operation, completeness and present service suitability have not been verified. No refurbishment, current calibration, certification or warranty is represented.\u003c\/p\u003e\n\u003ch3\u003eVisible condition and inspection limits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInterior covers are open and some connections appear disconnected or incomplete. Verify retained covers, tap hardware, bus links and cables before a completeness claim.\u003c\/li\u003e\n\u003cli\u003eInsulation resistance, transformer turns ratio, winding resistance, dielectric condition, temperature devices, grounding and suitability for re-energization were not tested.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOne Line Power dry-type motor-drive isolation transformer. The detailed plate states 2,500\/3,333 kVA continuous, 13,800 V primary, 480Y\/277 V secondary, 3 phase, 60 Hz, 150°C rise, 5.97% impedance and 9,360 lb total weight. The 72039 identifier also appears on the photographed core\/coil. A separate blue-plated 2,500 kVA enclosure is recorded as Transformer B and must not be merged into this item.\u003c\/p\u003e\n\u003ch3\u003eItem identification\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog reference\u003c\/th\u003e\n\u003ctd\u003eREM-TR-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer \/ marking\u003c\/th\u003e\n\u003ctd\u003eLine Power Manufacturing Corp., division of Electro-Mechanical Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel \/ type\u003c\/th\u003e\n\u003ctd\u003eDry Type Motor Drive Isolation Transformer AA (nameplate type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSerial \/ identifying number\u003c\/th\u003e\n\u003ctd\u003e72039 \/ I0108A (first I\/1 in suffix ambiguous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLot basis\u003c\/th\u003e\n\u003ctd\u003eOne recorded item or assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePhotographed markings and specifications\u003c\/h3\u003e\u003cp\u003eValues below describe visible nameplate or equipment markings. Original design ratings do not demonstrate current performance.\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNameplate type\u003c\/th\u003e\n\u003ctd\u003eDRY TYPE MOTOR DRIVE ISOLATION TRANSFORMER AA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRating\u003c\/th\u003e\n\u003ctd\u003e2,500\/3,333 kVA CONTINUOUS (as stamped; dual-rating conditions unverified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrimary voltage\u003c\/th\u003e\n\u003ctd\u003e13,800 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSecondary voltage\u003c\/th\u003e\n\u003ctd\u003e480Y\/277 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhases \/ frequency\u003c\/th\u003e\n\u003ctd\u003e3 phase \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection diagram\u003c\/th\u003e\n\u003ctd\u003eDelta primary \/ wye secondary with X0 terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e150°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpedance\u003c\/th\u003e\n\u003ctd\u003e5.97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSerial marking\u003c\/th\u003e\n\u003ctd\u003e72039 \/ I0108A (first I\/1 in suffix ambiguous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCore\/coil identification\u003c\/th\u003e\n\u003ctd\u003e72039 sticker matches main plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTotal unit weight\u003c\/th\u003e\n\u003ctd\u003e9,360 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrimary taps\u003c\/th\u003e\n\u003ctd\u003e14,490 \/ 14,145 \/ 13,800 \/ 13,455 \/ 13,110 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTap current table\u003c\/th\u003e\n\u003ctd\u003e99 \/ 102 \/ 104 \/ 107 \/ 110 A respectively\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTap link table\u003c\/th\u003e\n\u003ctd\u003e2–3 \/ 3–4 \/ 4–5 \/ 5–6 \/ 6–7 respectively\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNameplate drawing identifier\u003c\/th\u003e\n\u003ctd\u003eD4880A0005 (not represented as model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWinding conductor material\u003c\/th\u003e\n\u003ctd\u003eNot established from available evidence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eIncluded scope\u003c\/h3\u003e\u003cp\u003eTransformer A enclosure and matching core\/coil only. Adjacent switchgear and other transformers are excluded unless separately agreed.\u003c\/p\u003e\n\u003ch3\u003eIdentification and inspection notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThis record covers Transformer A and its matching core\/coil. The neighboring enclosure and switchgear are not included by default.\u003c\/li\u003e\n\u003cli\u003eThe serial suffix remains ambiguous between I0108A and 10108A.\u003c\/li\u003e\n\u003cli\u003eThe plate shows AA and 2,500\/3,333 kVA continuous. Any required cooling arrangement for the dual rating needs manufacturer confirmation.\u003c\/li\u003e\n\u003cli\u003eWinding conductor material has not been established from the photographs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLocation and fulfillment\u003c\/h3\u003e\u003cp\u003ePhotographed installed at the Remington Boiler\/Generator Plant, Ilion, New York, on August 28, 2026. These survey photographs do not confirm present stock location or immediate availability.\u003c\/p\u003e\n\u003cp\u003eAvailability, item release, included accessories, removal\/loading responsibilities, handling time and freight or parcel arrangements must be confirmed before an order is accepted. Packed dimensions and shipping weight are not established; shipping is quoted separately.\u003c\/p\u003e\n\u003cp\u003eElectrical, pressure-containing and process equipment requires assessment by qualified personnel before energization, installation or service.\u003c\/p\u003e\n\u003cp\u003eRequest availability, item details and a shipping quote using catalog reference REM-TR-01. Photos are of the surveyed equipment; surrounding items are not automatically included.\u003c\/p\u003e","brand":"Line Power Manufacturing Corp., division of Electro-Mechanical Corporation","offers":[{"title":"Used","offer_id":55980813484105,"sku":"REM-TR-01","price":37500.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0991\/2958\/9833\/files\/rem-tr-01-01-683aa1bbc42d.jpg?v=1788118000","url":"https:\/\/nyc-surplus.com\/products\/remington-tr-01","provider":"NYC Surplus","version":"1.0","type":"link"}