{"product_id":"remington-cb-17","title":"Used Siemens RL-2000 power breaker — 1,600 A sensors — CB-17","description":"\u003cp\u003e\u003cstrong\u003eCondition: Used.\u003c\/strong\u003e Untested industrial surplus. Operation, completeness and present service suitability have not been verified. No refurbishment, current calibration, certification or warranty is represented.\u003c\/p\u003e\n\u003cp\u003eSiemens RL-2000 low-voltage power circuit breaker with 2,000 A frame and marked 1,600 A current\/ground sensors. Electrically operated control equipment is marked 120 V AC. Nameplate lists 65 kA at 635\/508\/254 V AC; current trip settings and operating condition are unverified.\u003c\/p\u003e\n\u003ch3\u003eItem identification\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog reference\u003c\/th\u003e\n\u003ctd\u003eREM-CB-17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer \/ marking\u003c\/th\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel \/ type\u003c\/th\u003e\n\u003ctd\u003eRL-2000 LM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSerial \/ identifying number\u003c\/th\u003e\n\u003ctd\u003eR-96464A-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLot basis\u003c\/th\u003e\n\u003ctd\u003eOne recorded item or assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePhotographed markings and specifications\u003c\/h3\u003e\u003cp\u003eValues below describe visible nameplate or equipment markings. Original design ratings do not demonstrate current performance.\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog \/ model\u003c\/th\u003e\n\u003ctd\u003eRL-2000 LM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSerial number\u003c\/th\u003e\n\u003ctd\u003eR-96464A-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacture date\u003c\/th\u003e\n\u003ctd\u003e1992-07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame rating\u003c\/th\u003e\n\u003ctd\u003e2,000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstalled current \/ ground sensors\u003c\/th\u003e\n\u003ctd\u003e1,600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl power\u003c\/th\u003e\n\u003ctd\u003e120 V AC (motor, close and trip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterrupting rating\u003c\/th\u003e\n\u003ctd\u003e65 kA symmetrical at 635, 508 and 254 V AC; instantaneous and short-time rows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWiring references\u003c\/th\u003e\n\u003ctd\u003eBreaker 18-738-602-455; trip 18-738-600-410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstruction reference\u003c\/th\u003e\n\u003ctd\u003eSG-3068\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstalled trip device\u003c\/th\u003e\n\u003ctd\u003eRMS-TSG-TZ; part 18-483-905-508 (component RY-01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eIncluded scope\u003c\/h3\u003e\u003cp\u003eThe described item or lot only. Nearby piping, wiring, cabinets and separately catalogued equipment are not automatically included. Final included components and removal boundaries will be confirmed before sale.\u003c\/p\u003e\n\u003ch3\u003eIdentification and inspection notes\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eThe photographed RMS-TSG-TZ trip device (component reference RY-01) belongs to this breaker assembly and is not an additional independently available product.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eLocation and fulfillment\u003c\/h3\u003e\u003cp\u003ePhotographed installed at the Remington Boiler\/Generator Plant, Ilion, New York, on August 28, 2026. These survey photographs do not confirm present stock location or immediate availability.\u003c\/p\u003e\n\u003cp\u003eAvailability, item release, included accessories, removal\/loading responsibilities, handling time and freight or parcel arrangements must be confirmed before an order is accepted. Packed dimensions and shipping weight are not established; shipping is quoted separately.\u003c\/p\u003e\n\u003cp\u003eElectrical, pressure-containing and process equipment requires assessment by qualified personnel before energization, installation or service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact for more info\u003c\/strong\u003e about pricing, availability and shipping, using catalog reference REM-CB-17. Photos are of the surveyed equipment; surrounding items are not automatically included.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Used","offer_id":55980814925897,"sku":"REM-CB-17","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0991\/2958\/9833\/files\/rem-cb-17-01-df39129740dc.jpg?v=1788118021","url":"https:\/\/nyc-surplus.com\/products\/remington-cb-17","provider":"NYC Surplus","version":"1.0","type":"link"}